Configuring the Internal Baseband Source
R&S
®
SMW200A
303User Manual 1175.6632.02 ─ 30
This section comprises the settings necessary to configure the segment to be out-
put and adjust the trigger for the switch between the segments of the multi-seg-
ment waveform. The parameters displayed depend on the selected trigger source.
The provided parameters are identical with the parameters in the section "Next
Segment Trigger In" in the "Trigger" tab; for information see Chapter 5.10.3.5,
"Next Segment Trigger In Settings", on page 369.
If the current instrument configuration uses Coupled sources, the dialog displays a
table with up to 8 rows, where the number of rows corresponds to the number of
selected BB Signals (Tx Antennas) or Entities (Users, Cells).
Settings:
State............................................................................................................................303
Set To Default..............................................................................................................304
Use one Waveform for all basebands......................................................................... 304
Waveforms table......................................................................................................... 305
Load Waveform/File.................................................................................................... 305
Waveform Info.............................................................................................................305
Clock Frequency......................................................................................................... 306
Delay...........................................................................................................................306
RF Power Ramping with Burst Marker........................................................................306
Create Multi Segment................................................................................................. 306
Create Multi Carrier.....................................................................................................306
Test Signal Form......................................................................................................... 306
Create Test Signal.......................................................................................................307
State
Enables/disables ARB modulation. Switching on the ARB generator turns off all the
other digital standards and digital modulation types in the same signal path.