Signal Routing and System Configuration
R&S
®
SMW200A
172User Manual 1175.6632.02 ─ 30
Sets the recording duration for measuring the baseband input signal by
"Auto Level Set".
Note: For accurate level measurements, set the measurement period to a time value
that is long enough to capture several periods of the input signal.
Remote command:
[:SOURce<hw>]:BBIN:MPERiod on page 962
Auto Level Set
For CODER connectors:
Starts measuring the input signal for estimating the crest factor, the peak level, and the
Revel of the input signal.
See also "Fulfilling the prerequisites for a correct signal processing of the externally
supplied digital baseband signal" on page 121.
Remote command:
[:SOURce<hw>]:BBIN:ALEVel:EXECute on page 962
4.7 I/Q Digital Output Settings
Required Options
The equipment layout for output of digital I/Q signal (Standard baseband) includes:
Option standard baseband generator (R&S SMW-B10) per signal path
(incl. one digital interface DIG I/Q per installed option)
and option standard baseband main module, one/two I/Q paths to RF (R&S SMW-
B13/-B13T)
Up to two options digital baseband output (R&S SMW-K18) per required output
Up to four options fading simulator (R&S SMW-B14)
(incl. one digital interface DIG I/Q per installed option)
The equipment layout for the output of digital I/Q (Wideband baseband) includes:
2 options wideband baseband generator (R&S SMW-B9)
(incl. digital interfaces DIG I/Q 1/2 and HS DIG I/Q 1/2 and per installed option)
Option wideband baseband main module, two I/Q paths to RF (R&S SMW-B13XT)
Up to four options fading simulator (R&S SMW-B15)
(incl. one digital interface DIG I/Q per installed option)
Up to two options wideband digital baseband outputs R&S SMW-K19
For more information, see data sheet.
To access and configure the "I/Q Digital Output" settings in "System Configura-
tion > Mode > Standard"
The digital output connectors are located on the R&S SMW rear panel, see Chap-
ter 4.3.1, "Physical Location of the Input and Output Interfaces", on page 114.
I/Q Digital Output Settings

Table of Contents