Signal Routing and System Configuration
R&S
®
SMW200A
137User Manual 1175.6632.02 ─ 30
Settings:
Display........................................................................................................................ 137
Auto Connect.............................................................................................................. 137
Connect/Disconnect All Remote................................................................................. 137
Preset behavior: Keep connections to external instruments.......................................138
Connector Name.........................................................................................................138
Direction......................................................................................................................139
External Instrument.....................................................................................................140
I/Q Connection............................................................................................................ 140
Remote Connection Status......................................................................................... 141
Instrument Name.........................................................................................................142
RF Couple...................................................................................................................142
(Delta) RF Frequency/ RF Level................................................................................. 142
RF State......................................................................................................................143
Display
Filters the displayed connectors upon one of the following criteria:
"All Connectors"
No filter is applied.
"Mapped Connectors"
Displayed are only the connectors to which a stream is mapped.
(see "Map Stream X to Connector" on page 134).
Note: To prevent faults, use this filter before you further configure the
external instruments.
"Input Connectors/Output Connectors"
Filters the display according to connector direction.
Remote command:
:SCONfiguration:EXTernal:DISPlay on page 924
Auto Connect
With enabled auto connect function, the instrument automatically detects connected
external instruments and establishes the required connection.
If the "Auto Connect > Off", however, after a R&S SMW startup you have to revise the
test setup and perform the following:
●
Check whether the necessary connections between the R&S SMW and the exter-
nal instruments are still existing.
●
Prove that the remote control of the particular instruments is required.
●
Trigger the Connect All Remote function.
Remote command:
:SCONfiguration:EXTernal:ACONnect on page 924
Connect/Disconnect All Remote
Triggers the instrument to:
●
Establish the remote connections to all configured External Instruments.
●
To terminate all existing remote connections.
The external instruments are not removed from the list of external instruments.
Only the remote connection status changes.
System Configuration Settings