Signal Routing and System Configuration
R&S
®
SMW200A
137User Manual 1175.6632.02 ─ 30
Settings:
Display........................................................................................................................ 137
Auto Connect.............................................................................................................. 137
Connect/Disconnect All Remote................................................................................. 137
Preset behavior: Keep connections to external instruments.......................................138
Connector Name.........................................................................................................138
Direction......................................................................................................................139
External Instrument.....................................................................................................140
I/Q Connection............................................................................................................ 140
Remote Connection Status......................................................................................... 141
Instrument Name.........................................................................................................142
RF Couple...................................................................................................................142
(Delta) RF Frequency/ RF Level................................................................................. 142
RF State......................................................................................................................143
Display
Filters the displayed connectors upon one of the following criteria:
"All Connectors"
No filter is applied.
"Mapped Connectors"
Displayed are only the connectors to which a stream is mapped.
(see "Map Stream X to Connector" on page 134).
Note: To prevent faults, use this filter before you further configure the
external instruments.
"Input Connectors/Output Connectors"
Filters the display according to connector direction.
Remote command:
:SCONfiguration:EXTernal:DISPlay on page 924
Auto Connect
With enabled auto connect function, the instrument automatically detects connected
external instruments and establishes the required connection.
If the "Auto Connect > Off", however, after a R&S SMW startup you have to revise the
test setup and perform the following:
Check whether the necessary connections between the R&S SMW and the exter-
nal instruments are still existing.
Prove that the remote control of the particular instruments is required.
Trigger the Connect All Remote function.
Remote command:
:SCONfiguration:EXTernal:ACONnect on page 924
Connect/Disconnect All Remote
Triggers the instrument to:
Establish the remote connections to all configured External Instruments.
To terminate all existing remote connections.
The external instruments are not removed from the list of external instruments.
Only the remote connection status changes.