Remote control commands
R&S
®
RTM3000
617User Manual 1335.9090.02 ─ 09
<n> *
Selects the frame.
Return values:
<DataMiso> List of decimal values of data bytes
Example:
BUS:SPI:FRAM3:DATA:MISO?
-> 94,177,171,60,242,219,100,0
Usage: Query only
BUS<b>:SPI:FRAME<n>:WCOunt?
Returns the number of words in the specified frame.
Suffix:
<b>
.
1..4
<n> *
Selects the frame.
Return values:
<WordCount> Number of words
Usage: Query only
BUS<b>:SPI:FRAME<n>:WORD<o>:STARt?
Returns the start time of the specified data word.
Suffix:
<b>
.
1..4
<n> *
Selects the frame.
<o> *
Selects the word number.
Return values:
<StartTime> Range: depends on sample rate, record length, and time
base
Increment: depends on the time base
Default unit: s
Usage: Query only
BUS<b>:SPI:FRAME<n>:WORD<o>:STOP?
Returns the end time of the specified data word.
Suffix:
<b>
.
1..4
Serial bus analysis

Table of Contents