Remote control commands
R&S
®
RTM3000
701User Manual 1335.9090.02 ─ 09
MCData: mde code with data
*RST: BCRT
SEARch:PROTocol:MILStd:WCOunt:CONDition <Compare>
Searches for a comparison condition of the word count.
Parameters:
<Compare> OFF | EQUal | NEQual | GTHan | GEQual | LEQual | LTHan |
WITHin | OUTSide
*RST: OFF
SEARch:PROTocol:MILStd:WCOunt:MAXimum <WordCountMaximum>
Searches for the maximum word count.
Parameters:
<WordCountMaximum>
SEARch:PROTocol:MILStd:WCOunt:MINimum <WordCountMinimum>
Searches for the minimum word count.
Parameters:
<WordCountMinimum>
SEARch:PROTocol:MILStd:WSTart <WordStart>
Selects a word start to be searched for.
Parameters:
<WordStart> COMMand | STATus | DATA
*RST: COMM
17.11.9 ARINC 429 (option R&S RTM-K7)
ARINC 429 configuration...................................................................................... 701
ARINC 429 trigger.................................................................................................703
ARINC 429 decode results....................................................................................707
ARINC 429 search................................................................................................ 710
17.11.9.1 ARINC 429 configuration
BUS<b>:ARINc:BRMode................................................................................................ 702
BUS<b>:ARINc:BRValue................................................................................................ 702
BUS<b>:ARINc:POLarity................................................................................................ 702
Serial bus analysis