BUS<b>:ARINc:THReshold:HIGH <ThresholdHigh>
Sets the high threshold level of the signal.
Suffix:
<b>
.
1..4
Parameters:
<ThresholdHigh>
BUS<b>:ARINc:THReshold:LOW <ThresholdLow>
Sets the low threshold level of the signal.
Suffix:
<b>
.
1..4
Parameters:
<ThresholdLow>
17.11.9.2
ARINC 429 trigger
TRIGger:A:ARINc:DATA:CONDition................................................................................. 703
TRIGger:A:ARINc:DATA:MAXimum..................................................................................704
TRIGger:A:ARINc:DATA:MINimum...................................................................................704
TRIGger:A:ARINc:DATA:OFFSet..................................................................................... 704
TRIGger:A:ARINc:DATA:SIZE......................................................................................... 704
TRIGger:A:ARINc:ERRor:CODing................................................................................... 704
TRIGger:A:ARINc:ERRor:GAP........................................................................................ 705
TRIGger:A:ARINc:ERRor:PARity..................................................................................... 705
TRIGger:A:ARINc:FORMat............................................................................................. 705
TRIGger:A:ARINc:LABel:CONDition.................................................................................705
TRIGger:A:ARINc:LABel:MAXimum................................................................................. 706
TRIGger:A:ARINc:LABel:MINimum.................................................................................. 706
TRIGger:A:ARINc:SDI.................................................................................................... 706
TRIGger:A:ARINc:SSM...................................................................................................706
TRIGger:A:ARINc:TTIMe:CONDition................................................................................706
TRIGger:A:ARINc:TTIMe:MAXimum................................................................................ 706
TRIGger:A:ARINc:TTIMe:MINimum................................................................................. 706
TRIGger:A:ARINc:TYPE................................................................................................. 707
TRIGger:A:ARINc:WORD:TYPE......................................................................................707
TRIGger:A:ARINc:DATA:CONDition <Compare>
Define the operators for comparison of the decoded data condition with the specified
data.
Parameters:
<Compare> EQUal | NEQual | GTHan | GEQual | LEQual | LTHan | WITHin |
OUTSide