Remote control commands
R&S
®
RTM3000
761User Manual 1335.9090.02 ─ 09
17.12.16 Switching
POWer:SWITching:EXECute........................................................................................... 761
POWer:SWITching:GATE:CONDuction:STARt...................................................................761
POWer:SWITching:GATE:CONDuction:STOP...................................................................761
POWer:SWITching:GATE:NCONduction:STARt.................................................................762
POWer:SWITching:GATE:NCONduction:STOP................................................................. 762
POWer:SWITching:GATE:SWAVe.................................................................................... 762
POWer:SWITching:GATE:TOFF:STARt............................................................................ 762
POWer:SWITching:GATE:TOFF:STOP.............................................................................762
POWer:SWITching:GATE:TON:STARt..............................................................................762
POWer:SWITching:GATE:TON:STOP.............................................................................. 762
POWer:SWITching:REPort:ADD...................................................................................... 763
POWer:SWITching:RESult:CONDuction:ENERgy?............................................................ 763
POWer:SWITching:RESult:CONDuction:POWer?..............................................................763
POWer:SWITching:RESult:NCONduction:ENERgy?.......................................................... 763
POWer:SWITching:RESult:NCONduction:POWer?............................................................ 763
POWer:SWITching:RESult:TOFF:ENERgy?......................................................................763
POWer:SWITching:RESult:TOFF:POWer?........................................................................764
POWer:SWITching:RESult:TON:ENERgy?........................................................................764
POWer:SWITching:RESult:TON:POWer?......................................................................... 764
POWer:SWITching:RESult:TOTal:ENERgy?......................................................................764
POWer:SWITching:RESult:TOTal:POWer?........................................................................764
POWer:SWITching:TYPE................................................................................................764
POWer:SWITching:EXECute
Starts the switching loss measurement.
Usage:
Event
POWer:SWITching:GATE:CONDuction:STARt <StartTime>
Sets the start time for the conduction gate. This value is simultaneously the stop time
for the turn on gate.
Parameters:
<StartTime>
POWer:SWITching:GATE:CONDuction:STOP <StopTime>
Sets the stop time for the conduction gate. This value is simultaneously the start time
for the turn off gate.
Parameters:
<StopTime>
Power analysis (option R&S RTM-K31)