Remote control commands
R&S
®
RTM3000
714User Manual 1335.9090.02 ─ 09
SEARch:PROTocol:ARINc:WORD[:TYPE]
Selects the word type to be searched for.
The command is relevant if SEARch:PROTocol:ARINc:CONDition is set to WORD.
Parameters:
<WordType> STARt | STOP
17.12 Power analysis (option R&S RTM-K31)
● General................................................................................................................. 714
● Probe adjustment..................................................................................................716
● Report................................................................................................................... 717
● Consumption.........................................................................................................718
● Dynamic ON resistance........................................................................................ 720
● Power efficiency....................................................................................................721
● Current harmonic.................................................................................................. 723
● Inrush current........................................................................................................729
● Modulation analysis...............................................................................................730
● Turn on/off.............................................................................................................734
● Quality...................................................................................................................735
● Ripple....................................................................................................................739
● Slew rate............................................................................................................... 744
● S.O.A.....................................................................................................................750
● Spectrum...............................................................................................................758
● Switching...............................................................................................................761
● Transient response............................................................................................... 765
17.12.1 General
POWer:ATYPe...............................................................................................................714
POWer:AUToscale......................................................................................................... 715
POWer:AUToscale:CURRent...........................................................................................715
POWer:AUToscale:VOLTage........................................................................................... 715
POWer:ENABle............................................................................................................. 715
POWer:RESult:TABLe.................................................................................................... 715
POWer:SOURce:CURRent<n>........................................................................................715
POWer:SOURce:VOLTage<n>........................................................................................ 716
POWer:STATistics:RESet................................................................................................716
POWer:STATistics:VISible...............................................................................................716
POWer:ATYPe
Sets the type of power analysis measurement.
Power analysis (option R&S
RTM-K31)