Remote control commands
R&S
®
RTM3000
722User Manual 1335.9090.02 ─ 09
POWer:EFFiciency:RESult:EFFiciency:STDDev?
POWer:EFFiciency:RESult:EFFiciency:WFMCount?
Returns the corresponding statistic result for the efficiency.
●
[:ACTual]: current measurement result
●
AVG: average of the long-term measurement results
●
NPEak: negative peak value of the long-term measurement results
●
PPEak: positive peak value of the long-term measurement results
●
STDDev: standard deviation of the long-term measurement results
●
WFMCount: the number of waveforms used for the displayed results
Return values:
<WaveformCount>
Usage: Query only
POWer:EFFiciency:RESult:INPut:REALpower[:ACTual]?
POWer:EFFiciency:RESult:INPut:REALpower:AVG?
POWer:EFFiciency:RESult:INPut:REALpower:NPEak?
POWer:EFFiciency:RESult:INPut:REALpower:PPEak?
POWer:EFFiciency:RESult:INPut:REALpower:STDDev?
POWer:EFFiciency:RESult:INPut:REALpower:WFMCount?
Returns the corresponding statistic result for the input real power.
●
[:ACTual]: current measurement result
●
AVG: average of the long-term measurement results
●
NPEak: negative peak value of the long-term measurement results
●
PPEak: positive peak value of the long-term measurement results
●
STDDev: standard deviation of the long-term measurement results
●
WFMCount: the number of waveforms used for the displayed results
Return values:
<WaveformCount>
Usage: Query only
POWer:EFFiciency:RESult:OUTPut:REALpower[:ACTual]?
POWer:EFFiciency:RESult:OUTPut:REALpower:AVG?
POWer:EFFiciency:RESult:OUTPut:REALpower:NPEak?
POWer:EFFiciency:RESult:OUTPut:REALpower:PPEak?
POWer:EFFiciency:RESult:OUTPut:REALpower:STDDev?
POWer:EFFiciency:RESult:OUTPut:REALpower:WFMCount?
Returns the corresponding statistic result for the output real power.
●
[:ACTual]: current measurement result
●
AVG: average of the long-term measurement results
●
NPEak: negative peak value of the long-term measurement results
Power analysis (option R&S
RTM-K31)