POWer:EFFiciency:RESult:EFFiciency:STDDev?
POWer:EFFiciency:RESult:EFFiciency:WFMCount?
Returns the corresponding statistic result for the efficiency.
[:ACTual]: current measurement result
AVG: average of the long-term measurement results
NPEak: negative peak value of the long-term measurement results
PPEak: positive peak value of the long-term measurement results
STDDev: standard deviation of the long-term measurement results
WFMCount: the number of waveforms used for the displayed results
Return values:
<WaveformCount>
Usage: Query only
POWer:EFFiciency:RESult:INPut:REALpower[:ACTual]?
POWer:EFFiciency:RESult:INPut:REALpower:AVG?
POWer:EFFiciency:RESult:INPut:REALpower:NPEak?
POWer:EFFiciency:RESult:INPut:REALpower:PPEak?
POWer:EFFiciency:RESult:INPut:REALpower:STDDev?
POWer:EFFiciency:RESult:INPut:REALpower:WFMCount?
Returns the corresponding statistic result for the input real power.
[:ACTual]: current measurement result
AVG: average of the long-term measurement results
NPEak: negative peak value of the long-term measurement results
PPEak: positive peak value of the long-term measurement results
STDDev: standard deviation of the long-term measurement results
WFMCount: the number of waveforms used for the displayed results
Return values:
<WaveformCount>
Usage: Query only
POWer:EFFiciency:RESult:OUTPut:REALpower[:ACTual]?
POWer:EFFiciency:RESult:OUTPut:REALpower:AVG?
POWer:EFFiciency:RESult:OUTPut:REALpower:NPEak?
POWer:EFFiciency:RESult:OUTPut:REALpower:PPEak?
POWer:EFFiciency:RESult:OUTPut:REALpower:STDDev?
POWer:EFFiciency:RESult:OUTPut:REALpower:WFMCount?
Returns the corresponding statistic result for the output real power.
[:ACTual]: current measurement result
AVG: average of the long-term measurement results
NPEak: negative peak value of the long-term measurement results
Power analysis (option R&S
RTM-K31)

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Rohde & Schwarz RTM3K-COM2 and is the answer not in the manual?

Rohde & Schwarz RTM3K-COM2 Specifications

General IconGeneral
BrandRohde & Schwarz
ModelRTM3K-COM2
CategoryTest Equipment
LanguageEnglish

Related product manuals