Remote control commands
R&S
®
RTM3000
740User Manual 1335.9090.02 ─ 09
POWer:RIPPle:RESult:PDCYcle:WFMCount?...................................................................742
POWer:RIPPle:RESult:PEAK[:ACTual]?........................................................................... 742
POWer:RIPPle:RESult:PEAK:AVG?.................................................................................742
POWer:RIPPle:RESult:PEAK:NPEak?............................................................................. 742
POWer:RIPPle:RESult:PEAK:PPEak?..............................................................................742
POWer:RIPPle:RESult:PEAK:STDDev?........................................................................... 743
POWer:RIPPle:RESult:PEAK:WFMCount?.......................................................................743
POWer:RIPPle:RESult:PERiod[:ACTual]?.........................................................................743
POWer:RIPPle:RESult:PERiod:AVG?...............................................................................743
POWer:RIPPle:RESult:PERiod:NPEak?...........................................................................743
POWer:RIPPle:RESult:PERiod:PPEak?........................................................................... 743
POWer:RIPPle:RESult:PERiod:STDDev?.........................................................................743
POWer:RIPPle:RESult:PERiod:WFMCount?.....................................................................743
POWer:RIPPle:RESult:STDDev[:ACTual]?....................................................................... 743
POWer:RIPPle:RESult:STDDev:AVG?............................................................................. 743
POWer:RIPPle:RESult:STDDev:NPEak?..........................................................................743
POWer:RIPPle:RESult:STDDev:PPEak?..........................................................................743
POWer:RIPPle:RESult:STDDev:STDDev?........................................................................743
POWer:RIPPle:RESult:STDDev:WFMCount?....................................................................743
POWer:RIPPle:RESult:UPEak[:ACTual]?..........................................................................744
POWer:RIPPle:RESult:UPEak:AVG?............................................................................... 744
POWer:RIPPle:RESult:UPEak:NPEak?............................................................................744
POWer:RIPPle:RESult:UPEak:PPEak?............................................................................ 744
POWer:RIPPle:RESult:UPEak:STDDev?..........................................................................744
POWer:RIPPle:RESult:UPEak:WFMCount?......................................................................744
POWer:RIPPle:EXECute
Starts the ripple measurement.
Usage:
Event
POWer:RIPPle:REPort:ADD
Adds the result to the report list.
Usage:
Event
POWer:RIPPle:RESult:FREQuency[:ACTual]?
POWer:RIPPle:RESult:FREQuency:AVG?
POWer:RIPPle:RESult:FREQuency:NPEak?
POWer:RIPPle:RESult:FREQuency:PPEak?
POWer:RIPPle:RESult:FREQuency:STDDev?
POWer:RIPPle:RESult:FREQuency:WFMCount?
Returns the corresponding statistic result for the frequency.
●
[:ACTual]: current measurement result
●
AVG: average of the long-term measurement results
●
NPEak: negative peak value of the long-term measurement results
Power analysis (option R&S
RTM-K31)