Remote control commands
R&S
®
RTM3000
766User Manual 1335.9090.02 ─ 09
Usage: Query only
POWer:TRANsient:RESult:PEAK:VALue?
Queries the peak value.
Return values:
<PeakValue>
Usage: Query only
POWer:TRANsient:RESult:RTIMe?
Queries the rise time.
Return values:
<RiseTime>
Usage: Query only
POWer:TRANsient:RESult:SETTlingtime?
Queries the settling time.
Return values:
<SettlingTime>
Usage: Query only
POWer:TRANsient:SIGHigh <SignalHigh>
Sets the expected signal high voltage value.
Parameters:
<SignalHigh>
POWer:TRANsient:SIGLow <SignalLow>
Sets the expected signal low voltage value.
Parameters:
<SignalLow>
POWer:TRANsient:STARt <StartTime>
Sets the start time for the transient response measurement.
Parameters:
<StartTime>