TABLE 295 AP NAT gateway IP fall back detected for particular VLAN pool event (continued)
Event AP NAT gateway IP fall back detected for particular VLAN pool
Event Code 343
Severity Informational
Attribute "vlanId"="1", "natGatewayMac"="xx:xx:xx:xx:xx:xx", "apMac"="xx:xx:xx:xx:xx:xx"
Displayed on the web
interface
NAT fallback detected for VLAN [{vlanId}] by AP [{apMac}]. Bringing down
interface and switching traffic to AP [{natGatewayMac}].
Description This event occurs when any NAT gateway AP detects that other monitored NAT
gateway AP IP is up.
NAT VLAN capacity affected detected by NAT gateway AP at zone due
to three (3) consecutive NAT gateway AP IPs are down for particular
VLAN pool
TABLE 296 NAT VLAN capacity affected detected by NAT gateway AP at zone due to three (3) consecutive NAT gateway
AP IPs are down for particular VLAN pool event
Event NAT VLAN capacity affected detected by NAT gateway AP at zone due to three
(3) consecutive NAT gateway AP IPs are down for particular VLAN pool
Event Type apNATVlanCapacityAffected
Event Code 344
Severity Critical
Attribute "natGatewayIP1"=192.168.10.2", "natGatewayIP2"=192.168.10.3", "nat
GatewayIP3"= 192.168.10.4","vlanId"="2", "apMac"="xx:xx:xx:xx:xx:xx"
Displayed on the web
interface
NAT VLAN capacity affected is detected by NAT gateway AP [{apMac}] since
three (3) consecutive NAT gateway IPs
[{natGatewayIP1&&natGatewayIP2&&natGatewayIP3}] are down. The NAT traffic
for some of the clients may get affected for VLAN [{vlanId}].
Description This event occurs when NAT VLAN capacity affected is detected by NAT gateway
AP at zone. This is due to three (3) consecutive NAT gateway AP IP failure for a
particular VLAN pool.
NAT VLAN capacity restored detected by NAT gateway AP due to (at
least) one out of the three (3) consecutive NAT gateway AP IP were down
is now up
TABLE 297 NAT VLAN capacity restored detected by NAT gateway AP due to (at least) one out of the three (3)
consecutive NAT gateway AP IP were down is now up event
Event NAT VLAN capacity restored detected by NAT gateway AP due to (at least) one
out of the three (3) consecutive NAT gateway AP IP were down is now up
Event Type apNATVlanCapacityRestored
Event Code 345
Severity Informational
Attribute "natGatewayIP"="192.168.10.2", "apMac"="xx:xx:xx:xx:xx:xx"
Displayed on the web
interface
NAT VLAN capacity restored detected by DHCP NAT AP [{apMac}] one of the
NAT gateway IPs [{natGatewayIP}] is now up, out of three (3) consecutive NAT
Events Types
AP State Change Events
Ruckus SmartCell Gateway 200 Virtual SmartZone High Scale and SmartZone 300 Alarm and Event Reference Guide
186 Part Number: 800-71565-001 Rev A

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Ruckus Wireless Virtual SmartZone High Scale and is the answer not in the manual?

Ruckus Wireless Virtual SmartZone High Scale Specifications

General IconGeneral
BrandRuckus Wireless
ModelVirtual SmartZone High Scale
CategoryGateway
LanguageEnglish

Related product manuals