System Programming Codes (Expert Mode Codes)
P31003-H3560-S403-54-7620, 09/05
A-14 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual
pcodes.fm
20 5 1 5 FIN - for message waiting
20 5 1 6 CACH EKTS, select slot/port: 0 = off, 1 = on
20 5 2 PRI parameters
20 5 2 11 Protocol type:
11 = AT&T/Custom
12 = AT&T/NI2
13 = AT&T/NI2 OSA
14 = AT&T/4ESS
15 = Siemens/Custom
16 = Siemens/Custom OSA
17 = Siemens/NI2
18 = Siemens/NI2 OSA
19 = MCI/DEX600
20 = MCI/DMS250
21 = BELL/DMS100
22 = BELL DMS100 TNS
23 = Nortel/DMS100
24 = Nortel DMS100 TNS
25 = SPRINT/DMS250
26 = Westinghouse
27 = FTS/DMS250
28 = FTS/5ESS
29 = GENERIC/NI2
30 = GENERIC/NI2 OSA
31 = QSIG
32 = IDA-P
20 5 2 12 Frame/line/encod, select slot
0 = ESF/B8ZS/Normal
1 = SF/ZCS/Inverted
20 5 2 13 Inwats parameter
20 5 2 13 -
1
Route
20 5 2 13 -
2
DNIS
20 5 2 13 -
3
Entrance telephone ring destination
Table A-3 Expert Mode Codes