HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual
3-213
Boards for HiPath 3000
Peripheral Boards
3.3.19 SLU8R
Introduction
The SLU8R (Subscriber Line U
P0/E
Rack) boards provide eight ports for connecting optiset E
and optiPoint 500 telephones to HiPath 3500 and HiPath 3300 (19-inch housing).
Interfaces
Figure 3-83 SLU8R Interfaces (S30817-K922-Z301)
Table 3-97 SLU8R Contact Assignments
MW8
jack
X2, pin U
P0/E
ports
1 - 4
MW8
jack
X2, pin U
P0/E
ports
5 - 8
114 a 1 554 a 5
15 b 1 55 b 5
224 a 2 664 a 6
25 b 2 65 b 6
334 a 3 774 a 7
35 b 3 75 b 7
444 a 4 884 a 8
45 b 4 85 b 8
U
P0/E
ports
1–8
(8-pin MW8
jacks)
X1
50
2
To
CUPR
CUCR
X2
11
88
U
P0/E
1
U
P0/E
8

Table of Contents