System Data
P31003-H3560-S403-54-7620, 09/05
2-24 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual
sysdat.fm
Static Configuration Rules
2.5 Static Configuration Rules
In HiPath 3000/5000 V6.0, HG 1500 provides the resources named in Table 2-8 via the
HG 1500 boards defined as media gateways (= gateway HG 1500, see Page 10-39).
Table 2-9 shows the board-specific capacity limits (maximum configuration) for the correspond-
ing functions.
>
For information on the configuration of HG 1500 boards, refer to the HG 1500 Ad-
ministration Manual.
Table 2-8 Technical Data (Resources) of the HG 1500 Boards Defined as Media Gate-
ways
Resource HXGM3 HXGS3
HXGR3
STMI2
with-
out
PDM1
with 1
x
PDM1
with 2
x
PDM1
with-
out
PDM1
with 1
x
PDM1
without
PDMX
1
Routing channels
A routing channel is required, for ex-
ample, for making connections be-
tween two IP networks via ISDN (IS-
DN routing).
16 16 16
Gateway channels (DSP channels)
A gateway channel is required, for
example, for connection between an
IP workpoint client and a TDM work-
point client (for example, optiPoint
500).
16 24 32 8 16 32
Fax/modem channels (G.711) 16 24 32 8 16 32
Fax channels (T.38)
These are special hardware re-
sources which facilitate fax via vCA-
PI and fax via IP functionality with
the T.38 protocol.
323
Teleworker with AES encryption and
codec G.711/G.729
2
(Sampling
rate) 20 msec)
10 8 10