HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual
3-1
Boards for HiPath 3000
Overview
3 Boards for HiPath 3000
3.1 Overview
Functional overview of all boards used
7
Caution
The system must be powered down and de-energized before removing or inserting
all boards in the HiPath 3550, HiPath 3350, HiPath 3500, HiPath 3300 and before
removing or inserting the central boards of the HiPath 3800, HiPath 3750 and Hi-
Path 3700.
7
DANGER (for U.S. only)
To protect against surge voltage caused by lightning, the following boards require
secondary protection when their lines leave the building where the main distribution
frame is housed:
● CBCC / CBRC
● DIU2U**
● SLA16N / SLA24N
● SLMA / SLMA8
● TIEL*
● TMC16
● TMDID / TMDID8
● TMEW2
● TMGL4 / TMGL4R / TMGL8
● TMST1**
● TM2LP
● TST1**
● 8SLA
* If not connected to facility provider terminal equipment.
** When this module is connected to the public network, secondary protection must
be provided by the CSU.
Table 3-1 HiPath 3000 - Functional Overview of All Boards Used
Board Part number Model
Central boards
CBCC S30810-Q2935-A301 HiPath 3550/HiPath 3350
CBCPR S30810-Q2936-X HiPath 3750/HiPath 3700
CBRC S30810-Q2935-Z301 HiPath 3500/HiPath 3300