IP Protocols and Port Numbers Used with HiPath 3000/5000 V6.0
HG 1500
Media Pay-
load Handler
TCP 12052 HG 1500 Voice over IP:
media gateway
control
Yes
SNTP UDP 123 X HG 1500,
optiPoint 400,
optiPoint 410,
optiPoint 420,
optiPoint 600,
optiClient 130
Time server No
VCAPI TCP 12001 VCAPI client
(e.g. telematics
SW AVM
Fritz!32)
Call control and
media transmis-
sion
No
Accounting
Server
TCP 13042 IP accounting
(e.g TeleData
Office)
IP accounting No
SNMP (Get/
Set)
UDP 161 SNMP browser,
HiPath FM
SNMP browser,
HiPath FM
No
SNMP
(Traps)
UDP 162 X optiPoint 400,
optiPoint 410,
optiPoint 420,
optiPoint 600,
optiClient 130
Sending/receiv-
ing SNMP error
messages
No
DSL Diag-
nostics Serv-
er
UDP 12200 DSL Status Tool DSL status dis-
play
No
Call Address
Resolution
CAR
TCP 12062 X HG 1500 Call number serv-
er, call monitoring
(can be activated
via administra-
tion)
Yes
CAR Alive
with Ping
ICMP X Call monitoring
(can be activated
via administra-
tion)
Type 8; Code 0
Echo Request
Type 0; Code 0
Echo Reply
Table C-5 HG 1500 - IP Protocols and Port Numbers Used
Service/
Application
Proto-
col
Server
Port
Connect
With Oth-
er Servers
Possible Cli-
ents
Application Config-
urable

Table of Contents