Boards for HiPath 3000
P31003-H3560-S403-54-7620, 09/05
3-144 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual
boards.fm
Peripheral Boards
Assigning both CAS cables
The following CAS cables are connected to the backplane via two APPCU adapters:
symmetrical line (120 ohms), open end
coaxial line (75 ohms)
Table 3-56 Assigning the CAS cable S30267-Z167-A100
15-pin Sub-D connector
Pin
Function Color code
9 a-wire (T), transmit wht/blu
1 b-wire (R), transmit blu/wht
15 a-wire (T), receive wht/ora
8 b-wire (R), receive ora/wht
Table 3-57 Assigning the CAS cable S30267-Z80-A100
15-pin Sub-D connector
Pin
Function Wire
15 a-wire (T), receive BNC line, cable 1
8 b-wire (R), receive BNC shield, cable 1
9 a-wire (T), transmit BNC line, cable 2
1 b-wire (R), transmit BNC shield, cable 2