P31003-H3560-S403-54-7620, 09/05
HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual
3-151
Boards for HiPath 3000
Peripheral Boards
Technical connection conditions
Maximum supply current: approximately 34 mA; maximum supply voltage: approximately
40 Vdc
Ring voltage against negative supply voltage (a-wire (tip)/RING): two telephones maximum
Range, see Section 2.8
Loop current detection > 10 mA
Ground button detection > 20 mA
The transmission method can be configured country-specifically by entering the country
code.