EasyManua.ls Logo

Siemens Hipath 5000 - Page 426

Siemens Hipath 5000
1202 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Boards for HiPath 3000
P31003-H3560-S403-54-7620, 09/05
3-336 HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual
boards.fm
Peripheral Boards
The operating mode (short or long line with the appropriate flash times) can be set up for each
subscriber line interface with HiPath 3000 Manager E (the menu settings: Set up station –> Sta-
tion –> Param –> Flags).
Figure 3-142 16SLA (Not for U.S.) - Interfaces (S30810-Q2923-X)
Table 3-161 16SLA (Not for U.S.) - Contact Assignments
Contact X2
(T/R ports 1 to
4)
X3
(T/R ports 5 to
8)
X4
(T/R ports 9 to
12)
X5
(T/R
ports 13-
16)
1a 1a 5a 9a 13
2b 1b 5b 9b 13
3a 2a 6a 1a 14
4 b 2 b 6 b 10 b 14
5 a 3 a 7 a 11 a 15
6 b 3 b 7 b 11 b 15
7 a 4 a 8 a 12 a 16
8 b 4 b 8 b 12 b 16
T/R ports
1-4
Stns. 1 to 4
T/R ports
5-8
Stns. 5 to 8
X1
50
2
X2
X3
16SLA
1
8
1
8
X4
X5
1
8
1
8
T/R ports
9-12
Stns. 9 to 12
T/R ports
13-16
Stns. 13 to 16