sysdat.fm
P31003-H3560-S403-54-7620, 09/05
HiPath 3000 V6.0, HiPath 5000 V6.0, Provisional Service Manual
2-27
System Data
Dynamic Configuration Rules
In a straightforward IP network, the number of gateway channels must be greater than or equal
to the number of TDM lines.
The required number of HG 1500 boards for VoIP is determined by the sum of the gateway
channels, MOH channels and conference channels
17 – 38 8
39 – 54 10
55 – 70 12
71 – 86 14
87 – 96 15
97 – 101 16
102 – 136 20
137 – 172 24
173 – 210 28
211 – 247 32
248 – 324 40
325 – 402 48
403 – 481 56
482 – 562 64
563 – 726 80
727 – 890 96
891 – 1000 112
Table 2-10 Number of Required Gateway Channels (HG 1500 Boards)
IP workpoint clients in the system Required number of gateway channels