outdoor antenna installations (not typical). A value lower than (40) is not recom-
mended.
3.
Assign the STL 0 reference a reference priority by navigating to MANAGEMENT >
OTHER: Reference Priority.
4.
In the Configure Reference Priorities panel, click the + icon in the upper right corner. The
Add Reference window will open.
5.
Select a Priority Level:
a.
If STL is to be used as a backup to GPS: Select a Priority Level of 2.
b.
If STL is the only reference: Select a Priority Level of 1.
For Time and PPS, select STL 0. Click Submit.
6.
Verify your settings in the Reference Priority table, and ensure that the new reference is
Enabled.
Reviewing the STL Status
Validity Status
To check or monitor the validity of the STL reference:
1.
Navigate to INTERFACES > REFERENCES.
2.
In the References status panel, under STL 0, check the status indicator light:
Detailed Status
To obtain detailed STL status information:
SecureSync User Reference Guide 491
APPENDIX

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Spectracom SecureSync and is the answer not in the manual?

Spectracom SecureSync Specifications

General IconGeneral
ModelSecureSync
Time ReferenceGPS, GLONASS, BeiDou, Galileo, IRIG, NTP, PTP, 1PPS
DisciplinesGNSS, IRIG, PTP, NTP, SyncE
InputsGPS, GLONASS, BeiDou, Galileo, IRIG, NTP, PTP, 1PPS
OutputsNTP, PTP, 1PPS, IRIG
ProtocolsPTP, NTP, SNMP, SSH, HTTPS
Form Factor1U Rack-mount
RedundancyOptional redundant power supply
Security FeaturesPassword protection, access control lists, SSH, HTTPS, SNMPv3, NTP authentication, PTP authentication
Power Supply100-240 VAC, 50-60 Hz
Operating Temperature0°C to +50°C
Dimensions44.45 mm (H) x 482.6 mm (W)