102 TimeProvider 5000 Users Guide 098-00028-000 Revision F – May, 2012
Chapter 3
TimeProvider 5000 CLI Command Set
set alarm-config
Provisions the alarm state, alarm level, and reporting delay time for the specified
alarms.
Command Syntax:
To provision the state of the specified alarm number:
set alarm-config state {alarm [0 to max-alarm-id] | all}
{enable | disable}
To provision the Level of the specified Alarm number:
set alarm-config level {alarm [0 to max-alarm-id] | all}
{2 |3 | 4 | 5}
where:
2 - Critical
3 - Major
4 - Minor
5 - Event
To provision the reporting delay of the specified Alarm number in seconds:
set alarm-config delay {alarm [0 to max-alarm-id] | all}
[0 to 500000]
Range: Delay - 0 to 500,000 seconds
Default: Delay - 0 seconds
Example 1:
To Disable alarm #35
tp5000> set alarm-config state alarm 35 disable
Example 2:
To set the level of alarm #31 to Error - major (3)
tp5000> set alarm-config level alarm 31 3
Note: Use “show alarm-config” command to view the max-alarm-id of
current TP5000 release.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Symmetricom TimeProvider 5000 and is the answer not in the manual?

Symmetricom TimeProvider 5000 Specifications

General IconGeneral
BrandSymmetricom
ModelTimeProvider 5000
CategoryServer
LanguageEnglish

Related product manuals