108 TimeProvider 5000 Users Guide 098-00028-000 Revision F – May, 2012
Chapter 3
TimeProvider 5000 CLI Command Set
show auto-sync
Displays the auto sync state
Command Syntax:
show auto-sync
Example:
tp5000> show auto-sync
Response:
AUTO-SYNC - enable
Level : User, Config, and Admin
set auto-sync
Provisions the auto sync IOC time to IMC time. This parameter is used only when
the reference is set to time mode after the IOC has passed the warm-up state.
When auto sync is enabled, IOC time will be synchronized to IMC time if they are
different. If auto sync is disabled and IOC time is different from IMC time, an alarm
will be generated. The user can then use the “Sync TOD-Source now” command to
manually synchronize IOC time to IMC time.
Command Syntax:
set auto-sync {enable | disable}
Example:
tp5000> set auto-sync enable
Remarks: When the system is in warm-up state, IMC time and IOC time are always
synced automatically regardless of whether auto sync is enabled or not. Auto-sync
is not used in the frequency reference mode.
Level : Config and Admin only

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Symmetricom TimeProvider 5000 and is the answer not in the manual?

Symmetricom TimeProvider 5000 Specifications

General IconGeneral
BrandSymmetricom
ModelTimeProvider 5000
CategoryServer
LanguageEnglish

Related product manuals