254 TimeProvider 5000 Users Guide 098-00028-000 Revision F – May, 2012
Chapter 3
TimeProvider 5000 CLI Command Set
sync tod-source
Use this command to force the system to synchronize the phase and time to the
current reference. This command is required to clear alarmID 8 (manual sync IOC
to IMC required).
Command Syntax:
sync tod-source now
Example:
tp5000> sync tod-source now
Remarks: This command can cause jitter or jump of 1PPS output.
Level : Config and Admin only