098-00028-000 Revision F – May, 2012 TimeProvider 5000 Users Guide 223
Chapter 3
TimeProvider 5000 CLI Command Set
Reverse Flow Operational Min TDEV (ns) : 114.16
Reverse Flow Min Cluster Width (ns) : 100.00
Reverse Flow Mode Width (ns) : 2148.00
Correction Frequency (ppb) : 11.86
Phase correction (ppb) : 0.00
Output TDEV Estimate (ns) : 0.00
Residual phase error (ns) : 0.00
Minimal RTD (us) : 2.14
Operational Temperature Max (deg C) : 46.06
Operational Temperature Min (deg C) : 45.93
Operational Temperature Min (deg C) : 45.93
5 Minute Temperature Stability (mdeg C) : 216.75
60 Minute Temperature Stability (mdeg C) : 481.95
Timing Packet Rate GM1 (pkts/s) : 64
Timing Packet Rate GM2 (pkts/s) : 0
Timing Packet Rate Delay (pkts/s) : 64
Observation Interval (min) : 1
IPDV Threshold (usec) : 50.000
Pacing Factor for Jitter Computation : 16
Forward IPDV % Below Threshold : 100.0
Forward Maximum IPDV (usec) : 0.103
Forward InterPkt Jitter (usec) : 0.027
Reverse IPDV % Below Threshold : 100.0
Reverse Maximum IPDV (usec) : 0.111
Reverse InterPkt Jitter (usec) : 0.028
Reference : 192.168.106.14
GM1 Flow State : Normal
GM2 Flow State : Waiting for GM to respond to signaling
GM1 Clock id : 00:b0:ae:ff:fe:01:90:68
GM2 Clock id : 00:00:00:00:00:00:00:00
Last Firmware Upgrade status: No upgrade since powered
Level : Config and Admin only
set ptp-node
This command allows the user to provide a new Acceptable Master list to the TP500
client found at a specified IP address. If the targeted TP500 is reached, and certain
conditions are met, the TP500 client will accept the new acceptable-master list.
The acceptable master list command can also be sent to other clients that support
PTP management messages.
This command allows the user to upgrade the firmware on a targeted TP500 client.
This command can also be used to reboot the targeted TP500 client.
Command Syntax:
To set a new Acceptable Master list for the specified PTP port and client (master
2 is optional):

Table of Contents