098-00028-000 Revision F – May, 2012 TimeProvider 5000 User’s Guide 409
Appendix A System Messages
System Notification Messages
Ethernet port (ETH1
or ETH2) link down
(See Table A-2 for
Secondary Index Info)
IOC1
IOC2
EXPx
x = 09
7 Minor No <port> Ethernet port
link down
<port> PTP Ethernet
port link down
cleared
Check network
connections
None required
Manual sync IOC
time to IMC required
IMC 8 Minor No Manual sync IOC
time to IMC required
Manual sync IOC
time to IMC not
required
Sync IOC time to
clear alarm with
“sync tod-source
now” command
None required
Power out of range
(See Table A-2 for
Secondary Index Info)
IMC
EXPx
x = 09
9CriticalNo<x.x V> power out of
range (voltage
value)
<x.x V> power out of
range cleared
(voltage value)
Hardware failure -
Replace module
None required
GNSS/GPS
antenna voltage out
of range
IMC 10 Major No GNSS/GPS antenna
voltage out of range
(voltage value)
GNSS/GPS antenna
voltage out of range
cleared (voltage
value)
Check antenna
connections
None required
GNSS/GPS
antenna current out
of range
IMC 11 Major No GNSS/GPS antenna
current out of range
(current value)
GNSS/GPS antenna
current within range
(current value)
Check all cable and
antenna
connections, check
voltage suppressor
None required
GNSS/GPS
antenna
short-circuit
(See Table A-2 for
Secondary Index Info)
IMC 12 Minor No GNSS/GPS antenna
short-circuit (voltage
value)
GNSS/GPS antenna
short-circuit cleared
(voltage value)
Check all cable and
antenna
connections, check
voltage suppressor
None required
Table A-1. System Notification Messages (Continued)
Description
Comp
ID
Event
ID
MsgLevel