Field-IQ operation 13 Operations
For:
l Less skip: Set a high percentage when it is acceptable to apply outside the boundary.
l Less overlap: Set a low percentage when you do not want to apply outside the boundary. A
very low setting may cause some skip at the boundary.
On/off valve latency
This option allows for hardware delays by adjusting the amount of time needed before turning the
valves on or off. To use this option:
Measure the amount of time it takes (in seconds) for the system to reach the correct rate after you
have switched it on or off.
Enter a time between 0.0 - 10.0 seconds.
Intentional overlap
You can use this option to make sure that when applying, there are no gaps in coverage if you move
into an uncovered area or out of a covered area.
Setting Description
On overlap distance Exiting a covered area and switching the implement on
Off overlap distance Entering a covered area and switching the implement off
Target rate
Use this option to set the amount of product you want to apply (the target application rate ). Enter
a number between 1333 - 41333.
Valve aggressiveness
If you use an auto-steer system, such as an EZ-Steer® or Autopilot™ system, you can use this option
to adjust how the system responds to steering changes.
l A higher setting brings the vehicle back on line quickly, but may cause tight oscillations.
l A lower setting gives a more moderate response to bringing the vehicle back on line, but can
avoid overshoot.
Enter a setting between 50 - 150%.
Version 7.0, Revision A CFX-750 Display User Guide 233