13 Operations Field-IQ operation
Field-IQ master switch box
Note – All systems must have a Field-IQ master switch box.
Item Name Explanation
c
Increment/decrement
switch
Increases the applied amount by a set amount (the amount
set in the Setup screen, Rate tab).
d
Rate switch Preset Rate 1, preset Rate 2, or Manual rate.
e LED indicator
l Red: Unit is powered but not communicating with the
CFX-750 display.
l Green: Unit is powered and communicating with theCFX-
750 display.
l Yellow: Unit is initializing communications with the CFX-
750 display.
f Automatic/Manual section
switch
l Automatic mode: The CFX-750 display automatically
opens and closes sections when entering areas of overlap,
non-apply zones, or crossing boundaries.
l
Manual mode: The sections are controlled manually,
bypassing the CFX-750 display.
Note – You can switch from Automatic to Manual mode
while traveling.
234 CFX-750 Display User Guide Version 7.0, Revision A