Raven controller setup 5 Implement application controller setup
Raven controller setup
When using the Raven SCS 400 and 600 series controller with the CFX-750 display, keep in mind:
l The CFX-750 display cannot control the status of the Raven controller master or boom
switches. This means that the operator must remain in complete control of the sprayer at all
times.
l The CFX-750 display cannot automatically turn off the sprayer when going outside headlands,
across exclusion zones, or previously sprayed areas.
l The sprayer may not always switch off completely when the CFX-750 display sends a zero rate.
This means the operator may need to manually turn off the master switch to ensure that spray
is not applied.
l The only time the CFX-750 display sends a zero rate is when the sprayer is outside a
prescription boundary and the "Rate outside polygon" option is zero.
Note – The operator must ensure that the master switch is off when there is no field open so that
no spray is accidentally applied to areas that shouldn't be sprayed, for example, roads, paths, and
neighboring fields.
1. After you select Raven as your controller, the Output Port screen displays.
2.
Choose the port you want to configure.
Note – Do not configure the display to output NMEA messages on the same port that your
controller is connected to.
3.
On the Raven controller, configure the Data Menu settings.
Setting Set to...
Baud or Baud Rate 9600
GNSS Inac
DLOG or Data Log On
TRIG or Data Log Trigger Value 1
UNIT or Data Log Trigger Units sec
Note – At the GNSS group, if ‘Send time’, ‘Time acknowledge’ or ‘Close file’ displays, change
them to GNSS Inac. Otherwise, the DLOG or DATA LOG option will not display.
For more information on configuring and calibrating the Raven controller, refer to the Raven
instruction manual.