Traditional tank calculations
ADM003GVAE1005 283
Polynomial spherical tank
Where:
TOV =P·(Lx'+L0')³+Qn·(Lx'+L0')²+Rn·(Lx'+L0')+Sn+VR'
Ln-1= Lxw < Ln and n is an integer between 1 = n < 9
Lwx' =Lwx/1000
VR' = VR/1000
Lx = measured liquid level (mm)
L0 = correction volume (mm)
Ln = levels at the registered pointers (mm)
P = constant (±X. XXXXXXXXX)
Qn = constant (±XXX. XXXXXXX)
Rn = constant (±XXXX. XXXXXX)
Sn = constant (±XXXXXXX. XXX)
VR : correction volume (L)