Sample LPG calculation
ADM003GVAE1005 309
Tank data:
Input Data
Check Data
Radius R = 3000 mm
Tank Height HT = 6000 mm
Shell Thick THICK = 18 mm
Level H = 5062 mm
Liquid Temp TL = 18.5 °C
Vapor Temp TV = 21.3 °C
Vapor Pressure P = 9.1 barg
Liquid Density DENL 15°C = 505.0
Step3 VCF=0.98982 — Volume Correction Factor
DENL=499.76 — Liquid Density @ liquid temperature
Step4 ΔH
1
=15.86 — Gauge correction for float buoyancy
ΔH
2
= 0.3 — Gauge correction for thermal expansion
HC=5078.16 — Corrected gauge reading (level)
Step5 Interpolation uses points 4,5,6,7
VL=106.731 — Liquid value
Step6 CORRT = 1.000137 — Thermal correction
VLC = 106.837 Liquid volume
CORRP = 1.000856 — Pressure correction
Step 7 VCF = 0.98962
VLC15 = 105.728