ELECTRICAL INSTALLATION
84
AV7000 LINEAR CAMERA
INSTALLING THE OPTIONAL VGA / USB INTERFACE PANEL
KIT
An optional VGA / USB Interface Panel Kit (93A201204) replacement panel accessory
can be used to attach a monitor, keyboard and mouse to an installed AV7000 camera. In
this way, system status and statistics can be monitored local to a scan point or tunnel,
and the monitor, keyboard and mouse can be used to change parameters without the
need of an external computer.
To install the optional VGA / USB Interface Panel Kit:
1. Disconnect the power source from the AV7000 camera.
2. Remove the camera’s rear access panel by loosening the four screws at its corners.
ESD CAUTION: Observe precautions to prevent Electrostatic Discharge
(ESD). Use an ESD grounding wrist strap and avoid direct contact with cir-
cuit boards, which could be damaged by ESD.