CALIBRATING AV7000: DYNAMIC CALIBRATION
PRODUCT REFERENCE GUIDE
347
CALIBRATING AV7000: DYNAMIC CALIBRATION
Dynamic calibration is used to set up and calibrate a system in motion.
Follow these steps to configure e-Genius for Running Dynamic Calibration
1. The test target used for dynamic calibration uses 20 character Code 128 barcodes,
so e-Genius must be configured to accept those codes.
2. In the menu tree unde
r Modify Settings, navigate to Global Settings | Barcode
Settings | Barcode Settings Table. The Barcode Settings Table window opens.
3. Set the barcode menu to read the Picket Fence/Step Ladder Res Test Chart
(code 128 barcodes).
Preparing the Dynamic Calibration Test Box
1. Tape the Dynamic Focus Target and Picket Fence/Step Ladder Res Test Chart
on the 460x300x150 mm [18x12x6 in] test box as shown.
After calibration is completed, this barcode setting mu
st be removed if it is
not the customers expected barcode.