ELECTRICAL INSTALLATION
72
AV7000 LINEAR CAMERA
CBX800
Please verify that the CBX800 connection box is configured for the AV7000 application
as follows.
1. Set HOST RS485HD TERM switch to OFF.
2. Set Power Source Selector jumper to FROM SOURCE.
3. Set Shield jumper to FILTERED Earth.
4. Insert jumper wire in pin block from REF to ID+ (one jumper in either block is suffi-
cient).
5. Set DEVICE CHASSIS GROUNDING to Earth.
6. Set J16 Jumper 16 to right position.
7. Set POWER switch to ON.
8. Set ID-NET TERM switch to OFF.
Box Interior Diagram