EasyManuals Logo

Datalogic AV7000 User Manual

Datalogic AV7000
488 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #335 background imageLoading...
Page #335 background image
X-PRESS SINGLE PUSH BUTTON FUNCTIONALITY
PRODUCT REFERENCE GUIDE
315
Focus/Locate
This function causes the camera to automatically learn the fixed focus distance and sen-
sitivity. The Focus LED blinks to indicate this
state. To exit the Focus/Locate Mode, press
the X-PRESS button once.
The focus procedure is as follows:
1. Place a package with barcode at the desired fixed focus distance in the center of
the c
amera’s view.
2. Enter the focus function. The Focus LED will blink.
3. Wait until the Focus LED is steady. This indic
ates the camera has determined the
fixed focus distance and sensitivity.
4. To commit the settings and exit, press the XPress button once.
5. This procedure ends when the values are
committed or after a timeout of 60 sec-
onds. If it times out the data is not saved.
Setup
Once entered, the camera aiming laser is enabled. The SETUP LED blinks to indicate the
aiming laser is enabled. Use the aiming laser to aim the camera properly during mount-
ing.
To exit Setup Mode, press the X-PRESS push button once.
Setup Mode will timeout after about 5 minutes.
AutoLearn
Once entered, the reader starts a procedure to automatically detect and recognize bar-
code types. The LEARN LED blinks to indicate the Learn mode is enabled.
The AutoLearn procedure is as follows:
1. Place one or more barcode types in the camera view. Hold the Xpress button until
LEARN LED lights.
2. Wait until the LEARN LED stays steady (indic
ating the reader has detected the bar-
code.
3. To commit the learned barcode type(s) and exit, press the X-PRESS push button
twice.
4. AutoLearn will timeout 60 seconds after the last barcode type is decoded and no
learned
barcode type(s) will be committed.
If you do not want to accept the learned barcode, let it go and AV500/AV900 will time
ou
t. The learned barcode will not be committed.
By default, the Test mode exits automatically 60 seconds after the last bar
code is
decoded.
AutoLearn will only add new barcode type(s) to the configuration. The
function will
not drop or modify existing barcode type(s) enabled in the
configuration. AutoLearn will only enable a learned barcode type if the bar-
code type does not already exist in the configuration.

Table of Contents

Other manuals for Datalogic AV7000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Datalogic AV7000 and is the answer not in the manual?

Datalogic AV7000 Specifications

General IconGeneral
BrandDatalogic
ModelAV7000
CategoryDigital Camera
LanguageEnglish

Related product manuals