AUTOMATED MOUNTING CALIBRATION
PRODUCT REFERENCE GUIDE
239
Dynamic Calibration Errors
Failed to Find Checkerboard
Possible causes:
• Side railing is blocking the cameras view of the target
• Checkerboard was not in the cameras view
• Checkerboard is damaged
Possible Solutions:
• Try inducting the package a few inches from the left/right side of the trans-
port
Failed with Invalid Package Data
No difference in height detected between the two packages inducted. For side cameras
this would mean there was no left to right difference.
Failed with Invalid Target Rotation
The calibration target rotation is not correct. Reference the picture above for target
placement on a package.
Failed to Open Event Log
The log used to record event data could not be opened. Try to re-run the last package.
Failed with Invalid Trigger Data
Photo Sensor or Position Sensor data is missing. Check parameter settings and physical
connections.
Failed with Too Much Package Skew
Too much package skew detected. Re-run the package with less skew.
Failed with Missing Photo Sensor Data
Photo Sensor data is expected, but it was not received. Check your operating mode
parameters.
Failed with Missing Position Sensor Data
Position Sensor data is expected, but it was not received. Check your operating mode
parameters.
Failed with No Package Data Captured
No data was received for the last package. Try to re-run the last package.
Failed with Package was Run Beyond the Left Conveyor Edge
The last package was run too far to the left (beyond the left edge defined by the position
sensor).
Failed with Package was Run Beyond the Right Conveyor Edge
The last package was run too far to the right (beyond the right edge defined by the posi-
tion sensor).
Failed with Invalid Package Height Difference less than X mm
The difference in height was too small. The minimum difference in height is 203mm. For
side cameras this would mean there was not enough left to right difference.
Failed with Package Corner Could Not Be Found
The package corner could not be found in the embedded data. Try to re-run the last
package.
Failed with Too Much Package Height Variation
The height data reported by the position sensor varies by more than 50mm. Make sure
the package being used is not damaged and does not vary in height. If the package is not
the issue, check the position sensor.

Table of Contents

Other manuals for Datalogic AV7000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Datalogic AV7000 and is the answer not in the manual?

Datalogic AV7000 Specifications

General IconGeneral
BrandDatalogic
ModelAV7000
CategoryDigital Camera
LanguageEnglish

Related product manuals