MAINTENANCE
412
AV7000 LINEAR CAMERA
3. Check all cabling/conduit for signs of wear/damage. Repair/replace any damaged
cable connections as necessary.
Verify Barcode Reader Operation
If after performing maintenance, the imaging system continues to perform below the
normal operations experienced with the system under normal daily conditions, contact
Datalogic through our website at www.datalogic.com.
Verify Photoelectric Sensor Operation
1. Block the Photoelectric Sensor emitter beam to confirm it is aligned properly with
the reflector.
2. Verify that the TRIGGER LED on camera lights when photoelectric sensor beam is
blocked.
3. If the photoelectric sensor’s LED does not change status, adjust the photoelectric
sensor so that it is properly aligned with the reflector.
4. If the TRIGGER LED on the barcode reader does not light when the photoelectric
sensor’s beam is blocked, check the cabling between the photoelectric sensor and
CBX connection box for damage. 0.
Verify Tachometer Operation
1. Rotate the tachometer wheel slowly.
2. The TACH LED on camera’s connector panel should flash indicating the tachometer
is operational.