POWER SUPPLIES AND SUPPLY CAPACITY WHEN WIRING TO AI7000S
PRODUCT REFERENCE GUIDE
61
WIRING INTO THE CBX CONNECTION BOX
As shown below, loose-lead cables must pass through the water-tight seals in the base
of the CBX connection box (CBX100 shown). Insert the cables allowing enough slack for
the individual wires to reach the appropriate pin block connectors. Securely tighten the
water-tight seals after the cables have been inserted.
Insulation on individual wires should be removed to expose 13 mm [0.5 in] of bare
met
al before inserting into the pin block.
WARNING: DO NOT connect a separate power source to the CBX connection
box. The CBX receives its power through its connection to the AV7000.
Connecting a separate power source will be detrimental to the system
operation
WARNING: If you are terminating more than one wire in a single terminal,
cut off any
tinned ends and twist the wires together before inserting them
into the terminal.