TROUBLESHOOTING
426
AV7000 LINEAR CAMERA
BYPASSING AN AV7000 IN AN ARRAY (TUNNEL)
If for any reason, a slave AV7000 needs to be removed from an array (tunnel), it can be
bypassed to allow the array to continue functioning in a redundant loop, minimizing
down time.
To do this, remove the sync cables from SY
NC IN and SYNC OUT connectors of the slave
AV7000 and connect the sync cables end-to-end to complete the sync network. When
the slave AV7000 is ready to be brought back into the sync network, reattach the cables
to its SYNC IN and SYNC OUT ports. To bring the slave AV7000 back into the array clus-
ter.