1. From the Advanced Formatter window, select 1 from the Select an Advanced For-
matter to Modify drop-down list. This is the outgoing host message that will com-
bine the barcode data and scale (protocol index) message.
2. Click on the
Message Builder link. The Message Builder window opens.
3. Set up a Code (system barcode), and a delimitter to fall between the barcode data
and p
rotocol index data from the scale. See
“Advanced Formatter | Message
Builder” on page 208.
4. Click Add and select Code Related for the item type, to define the barcode as the
first part of the message.
5. Select
Code from the Code Related Items drop-down.
6. Click
Add and select String for the item type, to add a string to separate the code
and the scale data.
7. Select
Disabled, Previous Code or Next Code for the Link to Code drop-down.
8. Use the
to “Enter Text with the Text Entry Tool” on page 92 to create the
string.
9. Click
Add, to add in the scale message (Protocol Index).
10. Select
Global from the Item Type drop-down list.
11. Select
Protocol Index from the Global Items drop-down list.
12. Select
None from the Item Alignment drop-down.
13. Select
Decimal (ASCII) from the Item Data Format drop-down.
14. Select 2 (in this example) from the Transports drop-down list. This was selected as
th
e
Idx # in Global Settings | Communications | Transports.

Table of Contents

Other manuals for Datalogic AV7000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Datalogic AV7000 and is the answer not in the manual?

Datalogic AV7000 Specifications

General IconGeneral
BrandDatalogic
ModelAV7000
CategoryDigital Camera
LanguageEnglish

Related product manuals