E-GENIUS
202
AV7000 LINEAR CAMERA
Fill Character
For fixed length, click to “Enter Text with the Text Entry Tool” on page 92 and create
a fill character.
Code Identifier
Select Disabled, AIM, or Custom from the drop-down list. This parameter allows enabling/
disabling the transmission of the code ID in the output data format.
•
Disabled: No code identifier is included in the output message
•
AIM: The AIM standard identifier is included in the output message
•
Custom: This selection activates a list of Custom Code ID strings, allowing the user to
define an identifier string for each code symbology. The string will be included in the output
message.
In each code string option, click to
“Enter Text with the Text Entry Tool” on
page 92 and create a character string.
List of Code Types
This list appears when Custom is selected from the Code Identifier drop-down list. For each
code type, click to
“Enter Text with the Text Entry Tool” on page 92 and create
Code Identifier characters.