Error: No valid temperature
for laser #2
Error
The RangeFinder is unable to
read the laser temperature.
Internal RangeFinder failure.
Cycle the unit’s power. If the error
persists, replace the RangeFinder
and/or contact Datalogic Support.
Error: Sensor data always
from DOE #1
Error
Object data is always being
detected by DOE#1.
Object stuck on belt. Obstruc-
tion in the DOE laser pattern.
Beam blockers not set cor-
rectly.
Verify there are no objects or
obstructions in the DOE laser pat-
tern. Verify the Beam blockers are
set correctly. Cycle the unit’s power.
If the error persists, replace the
RangeFinder and/or contact Data-
logic Support.
Error: Sensor data always
from DOE #2
Error
Object data is always being
detected by DOE#2.
Object stuck on belt.
Obstruction in the DOE laser
pattern. Beam blockers not
set correctly.
Verify there are no objects or
obstructions in the DOE laser pat-
tern. Verify the Beam blockers are
set correctly. Cycle the unit’s power.
If the error persists, replace the
RangeFinder and/or contact Data-
logic Support.
Error: Sensor or laser problem
(no codewords)
Error
The RangeFinder is unable to
see the laser patterns.
There is an obstruction pre-
venting the sensor (in the
center of the RangeFinder) to
see the laser patterns. An
internal Sensor error. The
laser patterns are not present
or blocked.
Verify there are no obstructions
blocking the view of the sensor.
Verify there are no obstructions
blocking the laser pattern genera-
tors. Cycle the unit’s power. If the
error persists, replace the Range-
Finder and/or contact Datalogic
Support.
Error: Tach or Tach Sync prob-
lem (invalid speed)
Error
The RangeFinder missed a
tach sync pulse. The current
tach value does not match
the tach value in the tach
sync message.
Noise on the Ethernet cable
connected to the RangeFinder
or the tachometer. Device
connected without a breakout
cable connected to eliminate
tach and tach sync.
Make sure cables are not running
too close to a motor. Make sure a
breakout cable is used when a
computer is attached.
e-Genius Description Type Explanation Possible Cause Solution

Table of Contents

Other manuals for Datalogic AV7000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Datalogic AV7000 and is the answer not in the manual?

Datalogic AV7000 Specifications

General IconGeneral
BrandDatalogic
ModelAV7000
CategoryDigital Camera
LanguageEnglish

Related product manuals