EasyManua.ls Logo

HAIMA 7 - Page 496

HAIMA 7
654 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Alarm and Indication System
T-32
Steps Check Display Measures
4
Use the special tool (fuel and
temperature tester) or the
resistance to input the
resistance 60Ω into the
combination instrument
terminal 3E.
Go to the next step.
Other than the
above-said display.
Replace the combination instrument.
5
Use the special tool (fuel and
temperature tester) or the
resistance to input the
resistance 100Ω into the
combination instrument
terminal 3E.
Go to the next step.
Other than the
above-said display.
Replace the combination instrument.
DTC 25 Working signal to the water temperature gauge
Check Display State Measures
Wait for 2s after
the DTC 25
chosen.
The water temperature gauge will
display as per the following order
per 2s:
l HC (Center)CH
(Constant display)
The water temperature gauge is
normal.
Other than the above cases. Replace the combination
instrument.
Replace the combination instrument.
DTC 26 LCD (Liquid Crystal Display) Display
Check Display State Measures
Choose DTC
26.
Odometer /hodometer
l LCD (Liquid Crystal
Display) is in normal
display
The LCD is normal.
Other than the above cases. Replace the combination
instrument.
DTC 27 Working signal to the indoor light
Combination instrument connectors
Harness side connector
(Viewed from the harness side)
XMET18W016

Table of Contents