Alarm and Indication System
T-36
Steps Check Display Measures
2
Turn off the front fog lamp
switch. (Disconnect the
front fog lamp relay).
The signal input of combination
instrument is normal.
Measure the voltage of combination
instrument terminal 2N.
Is the voltage equal to 0V
l If this value is satisfied, replace the
combination instrument.
l If this value is unsatisfied, check the
following parts.
Front fog lamp switch
Harness (combination
instrumentfront fog lamp
relay).
DTC 41 Shift lock solenoid valve signal On/Off (signal of the P position)
Combination instrument connectors
Harness side connector
(Viewed from the harness side)
XMET18W19
Steps Check Display Measures
1
Set the shift lever in the
positions other than P.
Go to the next step.
Measure the voltage of combination
instrument terminal 4B.
Is the voltage equal to 0V
l If this value is satisfied, replace the
combination instrument.
l If this value is unsatisfied, check the
following parts.
Shift switch P.
Harness (ignition switchshift
lock solenoid valve (signal in the
position P)combination
instrument)