Error code Description Action
271.04 The media is late reaching the sensor (output pass
through) within the specified time.
This applies to:
• High capacity output
• Output expander
Go to
“Sensor (output pass through) late jam
service check” on page 142.
271.05 The media reached the sensor (output pass
through) but did not clear it in the specified time.
This applies to:
• High capacity output
• Output expander
Go to
“Sensor (output pass through) lingering
jam service check” on page 141.
27y.14 Media remains on the sensor (output pass through)
during the warm up sequence.
This applies to:
• High capacity stacker
• Mailbox
• Oset stacker
• Output expander
Go to
“Sensor (output pass through) static jam
service check” on page 143.
27y.15 Media remains on the sensor (mailbox empty)
during the warm up sequence.
This applies to:
• High capacity stacker
• Mailbox
•
Oset
stacker
• Output expander
Go to
“Sensor (mailbox empty) static jam
service check” on page 146.
27y.29 The media reached the sensor (output pass
through) but did not clear it in the specified time.
This applies to:
• High capacity stacker
• Mailbox
• Oset stacker
• Output expander
Go to
“Sensor (output pass through) lingering
jam service check” on page 141.
27y.50
27y.50 The sensor (left tamper HP) does not detect that the
tamper has moved from home position.
Go to
“Left tamper does not leave home
position failure (oset stacker) service check”
on page 147.
27x.51 The media is late reaching the sensor (output pass
through) within the specified time.
Note: This only applies to mailbox.
Go to
“Sensor (output pass through) late jam
service check” on page 142.
27y.51 The sensor (right tamper HP) does not detect that
the tamper has moved from home position.
Note: This only applies to the oset stacker.
Go to
“Right tamper does not leave home
position failure (oset stacker) service check”
on page 147.
271.52 The media reached the sensor (mailbox empty) but
did not clear it in the specified time.
Go to
“Sensor (output pass through) lingering
jam service check” on page 141.
7462
Diagnostic information
140