214323 347 Revision A
1020377
A
B
Figure 5.34: Parker Manifold
4. Parker manifold only: If adapter fitting (A)
(MD #245160) requires replacement, two nuts
(1 1/2-16 UN-2A) are needed to properly torque fitting to
manifold. To install adapter fitting, follow these steps:
1. Thread new adapter fitting (A) (MD #245160) into
manifold (B).
2. Thread one nut approximately 13 mm (0.5 in.) onto
adapter fitting.
3. Jam second nut against first, and torque to
8188 Nm (6065 lbf·ft). Remove both nuts.
1001164
B
A
Figure 5.35: Adapter Hydraulics
5. Turn the new filter (B) into manifold (A) until the seal
contacts the mating surface. Tighten the filter an
additional 1/2 to 3/4 turn by hand.
IMPORTANT:
Do NOT use a filter wrench to install the new filter.
Overtightening can damage the O-ring and filter.
1001163
A
B
Figure 5.36: Adapter Hydraulics Cover
6. Reinstall cover (B) with five screws (A).