8.3 Windrower Fault Codes
The Harvest Performance Tracker (HPT) displays the windrower fault codes as a sequence of three numbers (AAA.BBBBBB.
CC). The sequence is defined as follows:
AAA = The Source Address (SA) defines which module generated the fault.
BBBBBB = The SPN is the description of the unique fault value.
CC = The FMI indicated the faults level of severity.
Source address (SA) numbers refer to the following locations:
23: Harvest Performance Tracker (HPT) display
25: HVAC box
104: Master controller and connected extension modules
176: Roof relay module
178: Chassis relay module
190: Console and ground speed lever (GSL)