5.8 Every 50 Hours
Complete the following maintenance tasks every 50 hours of operation.
Clean the cab fresh air intake filter. For instructions, refer to 5.8.1 Fresh Air Intake Filter, page 380.
Grease caster bearings and pivots. For instructions, refer to 5.8.2 Greasing Windrower, page 383.
Grease top lift link pivots. For instructions, refer to 5.8.2 Greasing Windrower, page 383.
5.8.1 Fresh Air Intake Filter
The fresh air intake filter should be serviced every 50 hours under normal conditions and more frequently in severe
conditions.
1015298
A
Figure 5.65: Fresh Air Intake Filter Location
The fresh air intake filter is located outside the lower right rear
of cab (A).
Refer to 5.1.5 Filter Part Numbers, page 329 for the appropriate
part number.
Removing Fresh Air Intake Filter
The fresh air intake filter should be serviced every 50 hours under normal conditions and more frequently in severe
conditions.
DANGER
To prevent bodily injury or death from the unexpected startup of the machine, always stop the engine and remove the
key from the ignition before leaving the operators seat for any reason.
1. Shut down the engine, and remove the key from the ignition.
2. Open the hood. For instructions, refer to 5.3.1 Opening Hood, page 335.
MAINTENANCE AND SERVICING

Table of Contents

Other manuals for MacDon M1240