ND-70348 (E) CHAPTER 4
Page 128
Revision 4.0
ASYD
SYSTEM
DATA
TYPE
(SYS)
SYSTEM
DATA
INDEX
(INDEX)
0 – 511
DATA
(DATA)
00 – FF
(Hex)
BIT
CORRESPONDING
DATA
SYSTEM DATA CONTENTS
DATA
0/1
BIT
1
123
0
b
0
Not used (Assign by the AIOC command)
0
b
1
0
b
2
0
b
3
0
b
4
0
b
5
0
b
6
b
7
Not used
124 00 Not used
125
b
0
MFC Sender PAD Control
Note
Note:
Source signal is –8 dBm
b
1
b
2
b
3
b
4
MFC Signaling System
b
5
b
6
b
7
b
3
b
2
b
1
b
0
0 0 0 0 = –0 dB
0 0 0 1 = –2 dB
0 0 1 0 = –4 dB
0 0 1 1 = –6 dB
0 1 0 0 = –8 dB
0 1 0 1 = –10 dB
0 1 1 0 = –11.5 dB
0 1 1 1 = –14 dB
1 0 0 0–1111= Not used
b
3
b
2
b
1
b
0
0 0 0 0 = NEC Standard (Complies with the CCITT
MFC-R2) (USA default)
0 0 0 1 = Australia (Telecom Specification)
0 0 1 0 = Thailand (TOT Specification)
0 0 1 1 = Venezuela (Corpoven Specification)
0 1 0 0 = Korea
0 1 0 1 = Singapore (Telecom Specification)
0 1 1 0 = Not used
0 1 1 1 = Argentina
1 0 0 0 = Indonesia
1 0 0 1 = Mexico
1 0 1 0 = Brazil
1 0 1 1 = Chile
1 1 0 0 = Columbia
1 1 0 1 = India
1 1 1 0 = Kuwait
1 1 1 1 = Not used